150 mm on center in the field of the roof use two of the same deck welds or fasteners in the same deck rib in the perimeter fm 1 29 2 2 3 4.
Fm global roof deck fasteners.
An fm approved fully or partially adhered roof covering or mechanically attached roof covering when the in row fastener spacing is less than or equal to one half of the deck span is applied per proprietary listings.
The side laps of all other steel decks are secured using fasteners fm approved for securing steel deck laps.
Fm global insured wind losses aver aged us 400 million per year from 1998 2007 with 80 percent of the loss dollars related to roofing system failures.
Designed to help roofing professionals roofnav provides easy access to all roofing related information from the fm approvals approval guide and related installation recommendations from relevant fm global property loss prevention data sheets.
By 1986 fm global elected to prohibit not only hot asphalt application but cold adhesives as well.
Roofnav can take the guesswork out of configuring an fm approved roofing system leaving you to focus on what matters most.
The support fastener pattern should be determined for the type of fastener desired using the rdnp determined above.
We would like to show you a description here but the site won t allow us.
In january fm global significantly re vised its property loss prevention data sheet 1 29 roof deck securement and above deck roof components this data sheet is intended to provide fm global s recommendations for secure ment of roof decks to roof structures and the proper design and installation of above deck roof components insula tion membrane you need to be aware of the revisions because they may affect roof system design and limit the use of some products and systems.
Gradually more roofing jobs incorporated mechanical fasteners throughout the roof area.
If a specific fastening detail is required every 6 in.
For more information.
For 3n 3ni 3np 3na 3npa and 3nia steel roof decks above deck component fastener spacing is.
Fasteners continue to meet the approval requirements of fm approvals for use as a component in class 1 60 class 1 75 and class 1 90 wind uplift rated insulated steel deck roof constructions when installed as described in roofnav an on line resource of.
This section contains reports that are generated to update national and international codes and standards.
Designed to help roofing professionals roofnav provides easy access to the most up to date fm approved roofing related information and related installation recommendations from relevant fm global property.
In fact since 1998 approxi mately 1 128 roof related wind losses were reported to fm global totaling nearly us 1 7 billion protecting commercial roofing systems is the single most effective.