Consult with local authority having jurisdiction ahj to determine appropriate standards.
Fire rated doors with louvers.
Air louvers 1900a 20x12 b fire rated metal door louver adjustable with fusible link mineral bronze finish.
18 ga 1 2mm cold rolled steel finish.
Air louvers 1900a 18x18 b fire rated door louver adjustable with fusible link mineral bronze finish.
Grey primer beige or bronze enamel installation.
Model 1900a is rated for use in fire doors up to 1 1 2 hour rating.
Louvers may be provided for classified hollow metal type and composite type fire doors.
Alpine s fire shut rolling fire shutters smoke shutters are fire rated and classified by underwriter s laboratories for up to 3 hours of fire rated fire protection for your window.
Fm factory mutual does not allow the use of louvers in fire rated doors.
The fire shutters are ideal for small openings that require fire rated protection such as school.
Can ulc s104 nfpa252 ubc 7 2 94 ul10 b ul10 c.
I m trying to make sense whether or not louvers air transfer openings in fire rated doors are allowed in fire rated barriers.
Louvers must be located in the bottom half of the door.
Louver frame will be labeled with listing mark.
18 gauge crs frame.
This fire shutter can be operated manually or with a motor and is activated by the melting of a fusible link.
There are two additional types of louvers available for use on fire rated doors but they would require a variance from the local code official since they are not specifically allowed by the codes.
Our fire rated doors with louvers can also be used on a mechanical closet to seal off the room in the event of a fire.
Self attaching product fastens the auxiliary frame to the louver core thru the door cutout eliminating the need to drill holes in the door door thickness.
1 3 4 44mm is standard.
Fusible link louvers are a great way to add additional ventilation to a room or closet door that would otherwise be closed off to maintain the integrity of the firewall.
Installed in accordance with nfpa 80.
Although it seems clear that in incidental uses the cbc table 509 4 2 states doors shall not have air transfer openings when an auto sprinkler is permitted with ought fire barrier.
Constructed from 18 gauge steel this adjustable z blade fusible link louver is intended for use in fire rated commercial door applications.
It seems it should be interpreted visa versa as permitted with fire rated barrier.
Louvers may be provided for classified hollow metal type and.
One type is the advantage intumescent louver by zero international zero also offers the fb intumescent block.
Fire rated doors can be prepared for one listed fire rated louver.
The 1900 series steel fire rated louver door insert adds 45 free flow air ventilation to fire rated doors.
Model 1900 a is rated for use in fire doors up to 1 1 2 hour rating.
Commercial fire rated doors with louvers.