This module can be used to replace a cmx 2 mod.
Fire alarm relay interface module.
Gamewell fci silent knight firelite notifier siemens and est edwards are just a few name brand examples.
The intelligent fire alarm relay can only be used on intelligent fire alarm systems and is made specifically to work with particular brands of fire alarm systems.
We can use a relay to drop power to the electric lock or use an ip device that drops power using the network connection or add a power control box that drops power when the fire.
The tri r is designed to monitor a normally open n o dry contact.
A range of easy relay fire alarm relays are available from 12v and 24v dc coils to 230v ac 50 60hz coils.
Relay contains two isolated sets of form c contacts which operate as a dpdt switch and are rated in accordance with the table in the manual.
This new siemens tri r module siemens part 500 896224 is an intelligent relay monitoring interface module for use in mxl mxlv mxl iq fire alarm control panels facp.
The door access control reader and the electric lock can be wired to the fire alarm in a number of different ways.
Each relay output is intended for form c switching applications which do not require wiring supervision for the load circuit.
Idnet relay iams allow fire alarm control panels to control a remotely located form c contact using idnet addressable communications for both data and module power.
Integrating fire alarm control using direct wiring.
Each monitor input provides an interface between a fire alarm.
Now that you have a pr 1 switching the shunt trip circuit this becomes your ecid emergency control interface device and the wiring up to this relay needs to be supervised.
The module also has a panel controlled led indicator.
Interface module rs232 485 is designed for implementing the communication function between fire control panels and a personal computer or between fire control panels connected into a network.
Our newest addition to our fire alarm relays category is wireless fire alarm relay that allows a network of wireless relays with 4 inputs outputs to be connected.
The intelligent fire alarm relay.
The interface module reports the contact s status to the facp.
The module is installed in fire control panels fs5100 fs5200.
Circuit connections to the relay contacts are not su pervised by the module.
To save the cost of an additional addressable monitor module fmm 1 we can switch out the frm 1 with a fcm 1 addressable control module.
Typical applications would be for switching local power for control functions such as elevator capture or control of hvac components pressurization fans dampers etc.